Search This Blog

Friday, May 11, 2012

SAP Note 1265906 - CCMS Central Autoreactions Job: Concurrency Check


Symptom
The CCMS processes central auto-reactions with job SAP_CCMS_CENSYS_DISPATCHER.  This job ensures that it runs only once at any given time by setting a lock in the NetWeaver enqueue server.
At at least one customer site, the SAP_CCMS_CENSYS_DISPATCHER job failed to complete correctly and remained 'active' for a very long time in the background processing system, retaining its lock in the Enqueue server.
This failure prevented processing of new central automatic reactions until the problem was corrected.



Other terms
central automatic reactions


Reason and Prerequisites
Inadequate error recovery in the SAP_CCMS_CENSYS_DISPATCHER job in the event of problems in the background processing or enqueue server.


Solution
Apply the correction in the associated support package or correction.

With the correction, the report RSAL_CENSYS_TOOL_DISPATCHING which runs in the CENSYS job checks the age of the lock that is present in the event that cannot obtain the lock.

If the lock is older than a fixed interval of 850 seconds, then the central system dispatcher ignores the lock and processes any unprocessed central automatic reaction entries in the table CSMCENTOOL.
The central system dispatcher quits, however, without doing any further processing if it determines that there are more than two SAP_CCMS_CENSYS_DISPATCHER jobs running (itself and the stuck job that is holding the lock).  You can monitor for such occurrences by monitoring for aborted SAP_CCMS_CENSYS_DISPATCHER jobs.






Affected Releases
Software
Component
Release
From
Release
To
Release
And
subsequent
SAP_BASIS
70
700
701
 
SAP_BASIS
71
710
711
 

Correction delivered in Support Package
Support
Packages
Release
Package
Name
SAP_BASIS
700
SAP_BASIS
701
SAP_BASIS
710
SAP_BASIS
711



Read More @ https://service.sap.com/sap/support/notes/1265906